| Total Static Gross Weight (\(W_{\text{tare}} + W_{\text{live}}\)) |
2,350 kg |
| Effective Design Dynamic Gross Load |
2,650 kg |
| Calculated Minimum Capacity per Cell (\(E_{\max, \text{calc}}\)) |
1,104 kg |
| Recommended Standard Commercial Rating (\(E_{\max}\)) |
1,500 kg |
| Total Installed Scale Capacity (\(N \times E_{\max}\)) |
4,500 kg |
| Gross Load Cell Utilization Rate |
52.2 % |
| Scale Combined Physical Uncertainty (\(\Delta W_{\text{system}}\)) |
± 0.90 kg |
| Relative Uncertainty at Maximum Payload (\(W_{\text{live}}\)) |
0.060 % |
| Relative Uncertainty at Minimum Batch Target |
0.60 % |
| Estimated OIML Verification Interval (\(v_{\min} = E_{\max}/7000\)) |
0.214 kg |