Calculated Sizing & Accuracy Profile

Engineering ParameterCalculated Value
Total Static Gross Weight (\(W_{\text{tare}} + W_{\text{live}}\)) 2,350 kg
Effective Design Dynamic Gross Load 2,650 kg
Calculated Minimum Capacity per Cell (\(E_{\max, \text{calc}}\)) 1,104 kg
Recommended Standard Commercial Rating (\(E_{\max}\)) 1,500 kg
Total Installed Scale Capacity (\(N \times E_{\max}\)) 4,500 kg
Gross Load Cell Utilization Rate 52.2 %
Scale Combined Physical Uncertainty (\(\Delta W_{\text{system}}\)) ± 0.90 kg
Relative Uncertainty at Maximum Payload (\(W_{\text{live}}\)) 0.060 %
Relative Uncertainty at Minimum Batch Target 0.60 %